Triethylamine

Update time:2021/09/29 11:10:09  ???View:  
Triethylamine, an organic compound, named as N,N-diethylethylamine, is a colorless and transparent liquid with a strong ammonia odor, which slightly fumes in the air. It is soluble in water, soluble in ethanol and ether. The aqueous solution is weakly alkaline. Flammable and explosive. Toxic and highly irritating. Industrially, it is mainly used as solvent, curing agent, catalyst, polymerization inhibitor, preservative, and synthetic dyes.
Chemical properties
Organic bases, and inorganic acids to form soluble salts.  It is flammable. Its vapor and air can form an explosive mixture, which can cause combustion and explosion when exposed to open flames and high heat energy. It can react with oxidants. Its vapor is heavier than air and can spread to a considerable distance at a lower place, and will ignite when it encounters a fire source. Corrosive.
Storage and transportation method
The warehouse is ventilated, low temperature and dry; stored separately from oxidants and acids
Notes
Dangerous
Health hazards: It has a strong irritation to the respiratory tract, and can cause pulmonary edema and even death after inhalation. Oral corrosion of the mouth, esophagus and stomach. Eye and skin contact can cause chemical burns.
Explosion hazard: The product is flammable and has strong irritation.
First aid measures
Skin contact: Take off contaminated clothing immediately and rinse with plenty of running water for at least 15 minutes. Seek medical attention.
Eye contact: Lift the eyelid immediately, and rinse thoroughly with plenty of running water or normal saline for at least 15 minutes. Seek medical attention.
Inhalation: quickly leave the scene to a place with fresh air. Keep the airway unobstructed. If breathing is difficult, give oxygen. If breathing stops, give artificial respiration immediately. Seek medical attention.
Ingestion: Rinse mouth with water, drink milk or egg white. Seek medical attention.
Fire-fighting measures
Hazardous combustion products: carbon monoxide, carbon dioxide, nitrogen oxides.
Fire fighting method: spray water to cool the container, and if possible, move the container from the fire scene to an open place.
Extinguishing agent: alcohol-resistant foam, carbon dioxide, dry powder, sandy soil. Extinguishing with water is ineffective.
Leak handling
Emergency treatment: Quickly evacuate personnel from the contaminated area to a safe area, isolate them, and strictly restrict access. Cut off the fire source. It is recommended that emergency response personnel wear self-contained positive pressure respirators and anti-virus suits. Enter the scene from the upper wind. Cut off the source of leakage as much as possible. Prevent entry into restricted spaces such as sewers and flood drains.
Small leakage: Use sand or other non-combustible materials to absorb or absorb. It can also be washed with a large amount of water, and the washing water is diluted and put into the waste water system.
A large number of leaks: build a dike or dig a pit for storage. Cover with foam to reduce steam hazards. Spray water or foam to cool and dilute the steam to protect the on-site personnel. Use explosion-proof pump to transfer to tank truck or special collector, recycle or transport to waste disposal site for disposal.
Disposal and storage
Operation precautions: airtight operation, strengthen ventilation. Operators must undergo special training and strictly abide by the operating procedures. It is recommended that operators wear catheter-type gas masks, wear protective overalls and rubber oil-resistant gloves. Keep away from fire and heat sources, and smoking is strictly prohibited in the workplace. Use explosion-proof ventilation systems and equipment. Prevent the vapor from leaking into the air in the workplace. Avoid contact with oxidants and acids. The flow rate of the filling should be controlled to prevent the accumulation of static electricity. When handling, load and unload with care to prevent damage to packaging and containers. Equipped with corresponding types and quantities of fire-fighting equipment and leakage emergency treatment equipment. Empty containers may be harmful residues.
Storage precautions: Store in a cool, ventilated warehouse. Keep away from fire and heat sources. The storage temperature should not exceed 30°C. The packaging is required to be sealed and not in contact with air. It should be stored separately from oxidants and acids, and avoid mixed storage. Use explosion-proof lighting and ventilation facilities. It is forbidden to use mechanical equipment and tools that are prone to sparks. The storage area should be equipped with leakage emergency treatment equipment and suitable storage materials.
 
Storage and transportation characteristics
Fire fighting method: spray water to cool the container, and if possible, move the container from the fire scene to an open place.
Extinguishing agent: alcohol-resistant foam, carbon dioxide, dry powder, sandy soil. Extinguishing with water is ineffective.
------分隔線----------------------------

Service Hotline:

You only need a phone call, we will serve you attentively

Consult now
Copyright © Shandong Zhengji Chemical Co., Ltd.  All Rights Reserved   Case Number :魯ICP備20007847號-4 chemBlink Premium Supplier
少妇富婆高级按摩出水高潮| 一本色道久久99一综合| 激情无码人妻又粗又大| 99久久人妻精品免费二区| 日韩精品人妻系列无码专区| 麻豆一二三四区乱码| 欧美亚洲国产第一精品久久| 中文字幕无码中文字幕有码| 亚洲AV无码成人精品区天堂| 久久久亚洲欧洲日产国产成人无码| 中文字幕人妻少妇引诱隔壁| 国产欧美日韩A片免费软件| 亚洲综合狠狠丁香五月| 97在线观看在线观看| 亚洲av日韩av在线电影天堂| 久久99精品久久久久久久久久| 亚洲国产成人精品无码区2021| 午夜视频在线观看免费完整版| 四虎成人精品国产永久免费无码| 欧美熟妇性XXXX欧美熟人多毛| 色综合久久久久无码专区| 在线观看国产成人AV片| 国产精品无码专区| 精品国产一区AV天美传媒| 超薄肉色丝袜一区二区| 国精品午夜福利视频导航| 久久免费看少妇高潮v片特黄| 中文字幕乱码人在线视频1区| 99麻花传媒剧国产免费| 办公室撕开奶罩揉吮奶头在线观看| 亚洲AV无码成H在线观看| 国产成人亚洲精品青草天美| 中国浓毛少妇毛茸茸| 国产69精品久久久久999小说| 亚洲欧美日韩成人一区久久| 国产乱人伦偷精品视频免观看| 美女视频黄是免费| 欧美亚洲日韩不卡在线在线观看| 亚洲愉拍一区二区三区| 国产网红无码精品视频| 玩50岁四川熟女大白屁股直播|